Search results

Search for "capillary electrophoresis" in Full Text gives 7 result(s) in Beilstein Journal of Nanotechnology.

Metal-organic framework-based nanomaterials as opto-electrochemical sensors for the detection of antibiotics and hormones: A review

  • Akeem Adeyemi Oladipo,
  • Saba Derakhshan Oskouei and
  • Mustafa Gazi

Beilstein J. Nanotechnol. 2023, 14, 631–673, doi:10.3762/bjnano.14.52

Graphical Abstract
  • (ELISA), radioimmunoassay (RIA), surface-enhanced Raman spectroscopy (SERS), and capillary electrophoresis are common analytical techniques used to qualitatively or quantitatively determine pharmaceuticals in various matrices because they are sensitive (Figure 2), have a significant tolerable limit of
PDF
Album
Review
Published 01 Jun 2023

Design of surface nanostructures for chirality sensing based on quartz crystal microbalance

  • Yinglin Ma,
  • Xiangyun Xiao and
  • Qingmin Ji

Beilstein J. Nanotechnol. 2022, 13, 1201–1219, doi:10.3762/bjnano.13.100

Graphical Abstract
  • resonance [10], Fourier transform infrared spectrometry (FTIR) [11], UV–vis absorption spectrometry [12], mass spectrometry (MS) [13], titration microcalorimetry [14], high-performance liquid chromatography (HPLC) [15], gas chromatography (GC), capillary electrophoresis (CE) [16], and electrochemical chiral
PDF
Album
Review
Published 27 Oct 2022

DNA aptamer selection and construction of an aptasensor based on graphene FETs for Zika virus NS1 protein detection

  • Nathalie B. F. Almeida,
  • Thiago A. S. L. Sousa,
  • Viviane C. F. Santos,
  • Camila M. S. Lacerda,
  • Thais G. Silva,
  • Rafaella F. Q. Grenfell,
  • Flavio Plentz and
  • Antero S. R. Andrade

Beilstein J. Nanotechnol. 2022, 13, 873–881, doi:10.3762/bjnano.13.78

Graphical Abstract
  • ligands by exponential enrichment” (SELEX). In this study, we select an aptamer (termed ZIKV60) by capillary electrophoresis SELEX (CE-SELEX) to the Zika virus non-structural protein 1 (NS1) and counterselection against the NS1 proteins of DENV (serotypes 1, 2, 3, and 4) and YFV. The ZIKV60 dissociation
  • reported in an attempt to reduce processing time, generate aptamers with novel designs and functions, or increase the process throughput [14][15][16]. In particular, the CE-SELEX technique is a SELEX variation in which capillary electrophoresis (CE) is used to separate oligonucleotides that have bound to
  • incubated with 80 pmol of the ZIKV NS1 protein in borate buffer (60 mM) for 30 min, 200 rpm, at 37 °C. An incubation solution sample was submitted to separation by CE using a neutral capillary on a P/ACE MDQ capillary electrophoresis system (Beckman Coulter Inc., Fullerton, CA). The capillary was first
PDF
Album
Supp Info
Full Research Paper
Published 02 Sep 2022

The different ways to chitosan/hyaluronic acid nanoparticles: templated vs direct complexation. Influence of particle preparation on morphology, cell uptake and silencing efficiency

  • Arianna Gennari,
  • Julio M. Rios de la Rosa,
  • Erwin Hohn,
  • Maria Pelliccia,
  • Enrique Lallana,
  • Roberto Donno,
  • Annalisa Tirella and
  • Nicola Tirelli

Beilstein J. Nanotechnol. 2019, 10, 2594–2608, doi:10.3762/bjnano.10.250

Graphical Abstract
  • was converted into ζ-potential values by means of the Smoluchowski equation using Malvern Zetasizer software (v7.11). Capillary electrophoresis. Electrophoresis measurements were performed at 25 °C on a P/ACE MDQ Plus (SCIEX, Warrington, UK) equipped with a 50 cm effective length (70 cm total length
  • free HA after nanoparticle preparation. Left: The HA content of the different nanoparticle formulations (1 mg/mL, deionized water) was measured by capillary electrophoresis before and after dialysis (MWCO = 1,000 kDa). Results are expressed as the relative amount of complexed HA (incorporated in the
PDF
Album
Supp Info
Full Research Paper
Published 30 Dec 2019

Structural and optical properties of penicillamine-protected gold nanocluster fractions separated by sequential size-selective fractionation

  • Xiupei Yang,
  • Zhengli Yang,
  • Fenglin Tang,
  • Jing Xu,
  • Maoxue Zhang and
  • Martin M. F. Choi

Beilstein J. Nanotechnol. 2019, 10, 955–966, doi:10.3762/bjnano.10.96

Graphical Abstract
  • lowest separation resolution. Since the stationary phase used in size exclusion chromatography (SEC) has a high surface area, NCs with high surface activity can be irreversibly adsorbed by the column packing material, which limits its application to the separation of NCs. For capillary electrophoresis
  • nanoparticles (NPs). Although dialysis can be a useful means of removing impurities from NPs, it is a very time-consuming technique. Capillary electrophoresis provides an efficient and simple technique to fractionate water-soluble NCs [19], however it often depends on the specific core or ligand shell
PDF
Album
Full Research Paper
Published 25 Apr 2019

False positives and false negatives measure less than 0.001% in labeling ssDNA with osmium tetroxide 2,2’-bipyridine

  • Anastassia Kanavarioti

Beilstein J. Nanotechnol. 2016, 7, 1434–1446, doi:10.3762/bjnano.7.135

Graphical Abstract
  • properties of the degradation products via nanopore translocation can be evaluated to assure base calling quality in a DNA sequencing effort. Keywords: α-hemolysin; capillary electrophoresis; DNA sequencing; high-performance liquid chromatography; nanopores; osmium tetroxide bipyridine; osmylated oligos
  • (HPLC) or capillary electrophoresis (CE). It turns out that both analytical tools clearly resolve DNA from the OsBp label, which appears as a single peak with the methods used in this report. For the more typical cases where the oligo/DNA has 5 or more pyrimidines, the resolution between intact and
  • unnecessarily long. Protocol A results in over 90% T osmylation and less than 8% C-osmylation and protocol B results in 100% T + C osmylation. Capillary electrophoresis methods and analyses Analyses of the reaction mixtures were carried out using an Agilent 1600 CE instrument equipped with a diode array
PDF
Album
Supp Info
Full Research Paper
Published 12 Oct 2016

Single pyrimidine discrimination during voltage-driven translocation of osmylated oligodeoxynucleotides via the α-hemolysin nanopore

  • Yun Ding and
  • Anastassia Kanavarioti

Beilstein J. Nanotechnol. 2016, 7, 91–101, doi:10.3762/bjnano.7.11

Graphical Abstract
  • dA10dCdA9 is monitored by capillary electrophoresis (CE) analysis. Any side-reaction, or any backbone degradation, or oxidative damage would have been detectable as additional peaks with typical detectability of 0.1%. Any product formed by these processes is expected to retain some nucleotides, and
  • pore we also tested the later with a dA25 tail added either to the 3’- or the 5’-end (Table 1). The oligos used in this study were purchased from Integrated DNA Technologies, as PAGE-purified and desalted materials (Table 1). They were analyzed by capillary electrophoresis (CE) to assess purity, and
  • ; the peak height of both oligo and osmylated oligo reach 120 mAU. Capillary electrophoresis (CE) overlapping traces of oligodeoxynucleotides pGEX3’-dA25 intact and pGEX3’-dA25 at R1 and R2 levels of osmylation per protocols A and B, respectively (Experimental section, Part A). Materials are at
PDF
Album
Full Research Paper
Published 22 Jan 2016
Other Beilstein-Institut Open Science Activities